Description
D0412 Clinical Mini Centrifuge
This Clinical Centrifuge is ideal for the separation of serum, plasma, urea, blood samples and other routine applications in hospital and research laboratories. It conforms to international safety standards and regulations, have passed the explosion-proof test and are certified with CE, cTUVus and FCC. MCA test according to IEC/EN61010-2-20 including explosion-proof and bio-safe tests. Passed EN61010-2-101:2002 requirements for invitro diagnostic (IVD) medical equipment.
Features:
1. High accuracy of speed, excellent performance
2. CPU controls all operating parameters including speed and time
3. RPM or G-force can be set and displayed
4. Operation can be timed from 30 seconds to 99 minutes or continuous running
5. Timer commences once the set speed is reached, so the separation time is more accurate
6. Gentle braking at low speeds with efficient separation
7. Parameters can be modified after the set speed is reached
8. Quick spins are possible by pressing and holding PULSE key
9. Automatic release the lid when operation has stopped to save processing time
10. Easy-to-read backlit LCD processing display and sound alert
11. Can be pulse accelerated and held at speed
12. High strength plastic rotor and excellent balance technology for quiet and stable operation
13. Brushless motor drive quickly and effortlessly accelerates the rotor to set speed
Specifications:
Max. Speed [rpm] 300-4500, increment: 100
Max. RCF [×g] 2490×g, increment: 100×g
Speed Accuracy [rpm] ±20
Rotor Capacity 12×10ml/7ml/5ml; 8×15ml
Run Time 30sec-99min-HOLD (Continuous operation)
Driving Motor Brushless DC motor
Safety Devices Door interlock, Over-speed detector; Over-temperature detector; Automatic internal diagnosis
Power Single-phase, 110V-240V, 50Hz/60Hz, 3A
Noise level [dB] ≤56
Acceleration/Braking time [Sec] 20s↑20s↓
Dimensions [mm] (L)255 ×(W)245×(H)140
Weight: 6kg
Additional Features Speed/Acceleration switch; Short-time
Rotor type |
Available tubes |
Tube quantity |
Dimension (Ф×L mm) |
Adapters |
Maximum speed (rpm) | Radius (cm) |
A12-10P
|
15ml con | 8 | 17×120 | 4500 | 11 | |
1.5-5ml vacu
|
12 | 13×82 | A10P15 & plug | 4500 | 9.8 | |
4-7 ml vacu
|
12 | 13×106 | A10P15 |
4500 | 11 | |
16×75 | A10P15 & plug
|
9.8 | ||||
8.5-10 ml vacu | 12 | 16×107 | A10P15
|
4500 | 11 | |
2.7-3 ml (EU) collection tube | 12 | 11×66 | A10P15 & plug
|
4500 | 9.8 | |
7.5-8.2 ml (EU) collection tube |
12 | 15×92 | A10P15
|
4500 | 11 | |
REMARK: A12-10P rotor is made of plastic and cannot be autoclaved or UV irradiation, only ordinary sterilization can be used. |
Reviews
There are no reviews yet.